The accuracy requirements of the Agricultural Water Measurement regulation (California Code of Regulations Title 23 Section 597 or CCR 23 §597) apply to delivery volumes, not flow rate. Volumetric accuracy is a function of the accuracy of your velocity, cross-section flow area in duration measurements. Additionally, upstream and downstream water level fluctuations can impact overall volumetric accuracy.
Based on a series of detailed uncertainty analyses, the following percent accuracies were developed for the RemoteTracker system:
- Average pipe velocity: 3.7% (this includes typical impacts associated with fluctuating upstream and downstream water levels)
- Cross-section flow area: 2.0%
- Delivery duration: 1.5%
RemoteTracker Accuracy: 4.5% (sum of the squares square rooted)
As you can see, the percent accuracy in volume is computed as 4.5%. This is good enough for both the laboratory certification and the field inspection accuracy certification methodologies established in CCR 23 §597.